4" Magnum 20

The 4" Magnum 20 (DC) Double Check Backflow Valve prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. This product is designed for irrigation, plumbing, & some waterworks applications. The shut off valves do not include electronic alarm switches.

The smallest, lightest, most economical, best performing, and only all stainless steel backflow preventer. Period.

Approvals
Approved in the Horizontal & Vertical Up Orientation.
This Product is NOT UL or FM Approved


Important Note: Install with FLEX Couplings or Flange Adapters Only. DO NOT use RIDGED Couplings!

10% OFF MAGNUM ORDERS MORE THAN $5,000!

MSRP:

$1,179.00

Pro Price:

$939.00

The Magnum 20(X) Double Check Backflow Prevention Valve Assembly is designed to prevent non-health hazard pollutants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. This product is designed for the waterwork, plumbing, and irrigation markets only.

Maximum Working Pressure:
175psi (12.1 bar)
Temperature Range:
33° - 140°F (1° - 60°C)
End Connections
- IPS Groove for Steel Pipe:
AWWA C606
- Flange Adapters:
ANSI B16.1 Class 125
Lead Free:
0.25% Maximum by Weight

Flow Performance

Measures & Materials

Valve Housing:
304 Stainless Steel
Valve Cover:
304 Stainless Steel
SOV Disks:
EPDM/304SS:
SOV Shafts:
304 Stainless Steel
SOV Bearings:
Teflon/Bronze
Non Wetted Bolts:
Grade 8 Zinc Plated
Check Disks:
Silicone
Wetted Fasteners:
18-8 Stainless Steel
Check Springs:
17-7 Stainless Steel
Check Pins:
17-7/18-8 Stainless Steel
Check Seats:
Noryl Polymer
O-Rings:
Buna-N

Engineering & Specifications

The Magnum 20(X) Double Check Valve shall utilize two independent Dual Action Check modules and two integral resiliently seated shut-off valves all of which shall be contained within a single rigid valve housing constructed entirely of 304 stainless steel. Dual Action Check modules shall operate as a “poppet style” check under low flow conditions, operate as a “swing style” check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Assembly test cocks shall be handle-less and operate via a tamper resistant actuator. Assembly shall have a single full access service port and cover with an “inline” replaceable elastomer seal. Assembly shall be serviceable without special tools and approved for both horizontal and vertical applications.

TECHNOLOGY

Top

Dual-Action™ Check Modules

The Patented Dual-Action Check™ (US8875733) is the core technology behind the superior performance of Deringer Backflow Prevention Product Line. The Dual-Action Check™ combines all of the best features of industry standard “poppet” checks and “swing” checks into a single high performance check module.

  • Light weight engineered polymer components.
  • Modular for easy removal of complete check from body.
  • Easily disconnect spring tension for safe check servicing.
  • Replaceable Silicone Rubber Elastomer Disk.
  • Excellent resistance to fouling
Skewed View
Low Flow Poppet Action

Poppet Action

Features:

  • Initial 25% of check stroke is that of a poppet check.
  • Consistent static sealing
  • Excellent resistant to fouling
  • Reliable check closure
  • Stable flow characteristics at lower flow rates

Swing Action

Features:

  • Final 75% of check stroke is that of a swing check.
  • Minimal friction loss at high flow rates.
  • More linear flow path water through valve.
High Swing Action

Bow-Seal™ Full Access Cover

Bow Seal 1
Bow Seal 2

The Patented Bow-Seal™ Full Access Cover (US8844562) is pre-formed to cylindrical shape friendly to high fluid pressure. This allows the cover to be much thinner and lighter than traditional flat covers while still providing FULL and EASY access to Dual Action™ Check Modules.

Additional features include:
  • Light weight
  • Simple removal
  • No sliding seals
  • Full access to valve internals
  • No cumbersome and heavy couplings
Bow Seal 3
Bow Seal 4

Tamper Resistant Test Cock

The Magnum tamper resistant ½” and ¾” ball valves are the first handle-less test cocks found on large diameter backflow devices in the industry. The top of the valve actuation stem has a unique shape that uses an independent custom wrench to open and close test cocks. All test cocks are lead free and meet the SDWA requirements.

Magnum Backflow Preventer Tamper Resistant Test Cocks

DOWNLOADS

Top
Magnum 20 Specification sheet

Magnum Specification Sheets

The Magnum 20(X) Specification Sheet includes information on valve characteristics, flow performance data, approval status and engineering specifications for all sizes. This file can be downloaded as a PDF and saved for future use.

Download pdf button




Magnum 20 Brochure

Magnum Brochure

This brochure provides information on applications, approvals, engineering specifications, valve characteristics and flow performance data for the Magnum 20 backflow preventer.

Download pdf button




Tamper Switch Instructions

Maintenance Instructions

The Magnum 20 Maintenance Instructions provide step by step procedures for maintaining a 2" - 4” Magnum 20 backflow preventer. A printable PDF document and video of these instructions are both available.

Download pdf button




Tamper Switch Instructions

Gear Box Replacement

The Gear Box Replacement Instructions provide step by step procedures for replacing a 2" - 8” Magnum backflow preventer gear box. A printable PDF document of these instructions are available.

Download pdf button




Indicator Flag Adjustment Instructions

Indicator Flag Adjustment

The Indicator Flag Adjustment Instructions provides a step by step procedure for aligning the flag to fully open and fully close on the backflow preventor gear box. A printable PDF document of these instructions is available.

Download pdf button




Low Flow Poppet Action

Product Warranty

This printable document provides information for the Backflow Direct one year warranty for Deringer and Magnum backflow preventers.

Download pdf button View Video Button