Deringer 50G (RPDA-II)
Reduced Pressure Detector Backflow Preventer w/ OS&Y Gate Valves
The Deringer 50G Reduced Pressure Detector Backflow Preventer w/ OS&Y Gate Valves prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur.
The smallest, lightest, most economical, best performing, and only all stainless steel backflow preventer. Period.
The Deringer 50G Reduced Pressure Detector Assemby prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire sprinkler systems when monitoring of unauthorized water use is required.

Maximum Working Pressure: 175psi (12.1 bar)
Temperature Range: 33 to 140 deg F (1 to 60 deg C)
Lead Free: 0.25% Maximum by Weight
End Connections:
Flange Adapters: ANSI B16.1 Class 125
IPS Groove for Steel Pipe: AWWA C606
Micro type-II Bypass Assembly
The type-II bypass assembly is a new technology to the backflow industry and is used on Backflow Direct"s Deringer 50 (RPDA-II). As more manufacturers begin to utilize this technology it is only a matter of time before it"s widely used and is more commonly seen than the old type-I bypass assembly. We created this video to provide a clear explanation on how the type-II bypass provides the EXACT same level of protection as a type-I bypass as well as some of the similarities and differences between the two.
Rate of Flow:

Dimensions:

Materials:
Valve Housing: 304 Stainless Steel
Valve Cover: 304 Stainless Steel
Bypass Spring: 302 Stainless Steel
RV Spring: 302 Stainless Steel
Non Wetted Bolts: Grade 8 Zinc Plated
Check Disks: Silicone
Wetted Fasteners: 18-8 Stainless Steel
Bypass Components: Lead Free Bronze
RV Housing: 304 Stainless Steel
Check Springs: 17-7 Stainless Steel
Check Pins: 17-7/18-8 Stainless Steel
Check Seats: Noryl Polymer
O-Rings: Buna-N
Bypass Internals: ABS Polymer
RV Hose: Braided Stainless Steel Wire
Gate Valve: Stem includes tamper switch groove
Gate Valve: Serviceable inline
Gate Valve: AWWA C509/UL/FM resilient seat (OS&Y)
Gate Valve: Flanged End ANSI B16.1 Class 125
Coupling: Flexible Grooved UL/FM
Engineering Specifications
The Deringer 50GX Reduce Pressure Detector (RPDA-II) Valve shall utilize two independent Dual Action Check modules contained within a single valve housing constructed of entirely of stainless steel. Dual Action Check modules shall operate as a poppet style check under low flow conditions, operate as a swing style check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Valve assembly shall include two resiliently seated and inline serviceable AWWA C509 gate valves of type outside yoke and stem (OS&Y). Gate valves shall utilize a stainless steel stem with a pre-machined groove for installation of supervisory tamper switches. Assembly test cocks shall be handle-less and operate via a tamper resistant actuator. Assembly shall utilize a single full access service port and a cover with an inline replaceable elastomer seal. Relief valve shall operate without the use of sliding seals and shall be constructed entirely of stainless steel. The bypass assembly shall include a meter registering gallons or cubic feet, a single check valve and test cocks. Assembly shall be serviceable without the use of special tools.
Maximum Relief Valve Discharge Rates

Deringer Specification Sheets
The Deringer 50G Specification Sheet includes information on valve characteristics, flow performance data, approval status and engineering specifications for all sizes. This file can be downloaded as a PDF and saved for future use.
Deringer 50G Specification Sheet
Maintenance Instructions
The Deringer 40G/50G Maintenance Instructions provide step by step procedures for maintaining a 2 to 4 inch Deringer 40G/50G backflow preventer. A printable PDF document is available.
Deringer 40G/50G Maintenance Instructions
Maintenance Video - 2 to 4" Deringer 50
Tamper Switch Procedure
The Deringer Gear Box Tamper Switch Procedure provides a step by step instructions for positioning the wiring of the Deringer gear box for fire alarm protection. A printable PDF document of these instructions is available.
Bypass Testing Instructions
One Year Warranty
Backflow Direct warrants its product to be free from defects in material and workmanship under normal operating conditions for a period of one year from the date of original shipment. In the event of such defects within the warranty period, Backflow Direct retains the exclusive right to repair or replace (with a new or newly rebuilt product) the device or offer a full refund of the original purchase price at its sole discretion. Backflow Direct assumes no liability for replacement of inoperative products beyond the warranty period.
THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE.
THE REMEDY ABOVE SHALL BE THE SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. Backflow Direct shall not be responsible for any special, consequential or incidental damages, including without limitation, repair costs or lost profits or property damage as a result of product malfunction or any other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, adverse water conditions or any other circumstances over which Backflow Direct has no control. SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, IN SUCH STATES, THE ABOVE LIMITATIONS MAY NOT APPLY.
This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the products.
To obtain warranty service, contact us for further instructions. When credit is issued it will be at the original purchase price.
Product Specific Warranty
1) NRS, OS&Y and/or any Gate Valves utilized as shut off valves on Backflow Direct products are covered by original manufacturer's warranty ONLY.
2) Reduced Pressure Principle Backflow Preventers (RP or RPDA) can and WILL discharge water. NEVER install an RP or RPDA in a location where any amount of discharge from the Relief Valve will cause property damage. For an indoor, pit, vault, mechanical room or enclosure installation of an RP or RPDA an auxiliary drain (SEPARATE AND INDEPENDENT of the Air Gap Assembly) is REQUIRED and MUST be properly sized for the Maximum Relief Valve Discharge Rate corresponding to the system/supply pressure. Backflow Direct shall not be responsible for any special, consequential or incidental damages, including without limitation, repair costs, lost profits, property damage, or any other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, adverse water conditions or any other circumstances, caused by lack of auxiliary drain, location of auxiliary drain or undersized auxiliary drain.
3) Air Gap Assembly will capture and evacuate light water discharge from the Relieve Valve caused by daily fluctuation in system/supply pressure. An Air Gap Assembly will NOT capture and evacuate the Maximum Relief Valve Discharge Rate caused by catastrophic valve or system failure. An auxiliary drain (separate and independent of the Air Gap Assembly) is REQUIRED and MUST be properly sized for the Maximum Relief Valve Discharge Rate. Backflow Direct shall not be responsible for any special, consequential or incidental damages, including without limitation, repair costs, lost profits, property damage, or any other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, adverse water conditions or any other circumstances, caused by lack of auxiliary drain, location of auxiliary drain or undersized auxiliary drain.
This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the products.
To obtain warranty service, contact us for further instructions. When credit is issued it will be at the original purchase price.